diff options
author | Bryan O'Sullivan <bos@lindenlab.com> | 2008-06-02 21:14:31 +0000 |
---|---|---|
committer | Bryan O'Sullivan <bos@lindenlab.com> | 2008-06-02 21:14:31 +0000 |
commit | 9db949eec327df4173fde3de934a87bedb0db13c (patch) | |
tree | aeffa0f0e68b1d2ceb74d460cbbd22652c9cd159 /indra/tools | |
parent | 419e13d0acaabf5e1e02e9b64a07648bce822b2f (diff) |
svn merge -r88066:88786 svn+ssh://svn.lindenlab.com/svn/linden/branches/cmake-9-merge
dataserver-is-deprecated
for-fucks-sake-whats-with-these-commit-markers
Diffstat (limited to 'indra/tools')
-rw-r--r-- | indra/tools/vstool/README.txt | 9 | ||||
-rw-r--r-- | indra/tools/vstool/VSTool.csproj | 95 | ||||
-rwxr-xr-x | indra/tools/vstool/VSTool.exe | bin | 0 -> 24576 bytes | |||
-rw-r--r-- | indra/tools/vstool/VSTool.sln | 19 | ||||
-rw-r--r-- | indra/tools/vstool/main.cs | 529 |
5 files changed, 652 insertions, 0 deletions
diff --git a/indra/tools/vstool/README.txt b/indra/tools/vstool/README.txt new file mode 100644 index 0000000000..e419180031 --- /dev/null +++ b/indra/tools/vstool/README.txt @@ -0,0 +1,9 @@ +VSTool is a command line utility to manipulate VisualStudio settings.
+
+The windows cmake project configuration uses VSTool.exe
+
+A handy upgrade:
+ figure out how to make cmake build this csharp app
+ - or write the app using script (jscript?!?) so it doesn't need to be built.
+
+
diff --git a/indra/tools/vstool/VSTool.csproj b/indra/tools/vstool/VSTool.csproj new file mode 100644 index 0000000000..24f1031f81 --- /dev/null +++ b/indra/tools/vstool/VSTool.csproj @@ -0,0 +1,95 @@ +<Project DefaultTargets="Build" xmlns="http://schemas.microsoft.com/developer/msbuild/2003">
+ <PropertyGroup>
+ <ProjectType>Local</ProjectType>
+ <ProductVersion>8.0.50727</ProductVersion>
+ <SchemaVersion>2.0</SchemaVersion>
+ <ProjectGuid>{96943E2D-1373-4617-A117-D0F997A94919}</ProjectGuid>
+ <Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration>
+ <Platform Condition=" '$(Platform)' == '' ">AnyCPU</Platform>
+ <ApplicationIcon>
+ </ApplicationIcon>
+ <AssemblyKeyContainerName>
+ </AssemblyKeyContainerName>
+ <AssemblyName>VSTool</AssemblyName>
+ <AssemblyOriginatorKeyFile>
+ </AssemblyOriginatorKeyFile>
+ <DefaultClientScript>JScript</DefaultClientScript>
+ <DefaultHTMLPageLayout>Grid</DefaultHTMLPageLayout>
+ <DefaultTargetSchema>IE50</DefaultTargetSchema>
+ <DelaySign>false</DelaySign>
+ <OutputType>Exe</OutputType>
+ <RootNamespace>VSTool</RootNamespace>
+ <RunPostBuildEvent>Always</RunPostBuildEvent>
+ <StartupObject>VSTool.VSToolMain</StartupObject>
+ <FileUpgradeFlags>
+ </FileUpgradeFlags>
+ <UpgradeBackupLocation>
+ </UpgradeBackupLocation>
+ </PropertyGroup>
+ <PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Debug|AnyCPU' ">
+ <OutputPath>.\</OutputPath>
+ <AllowUnsafeBlocks>false</AllowUnsafeBlocks>
+ <BaseAddress>285212672</BaseAddress>
+ <CheckForOverflowUnderflow>false</CheckForOverflowUnderflow>
+ <ConfigurationOverrideFile>
+ </ConfigurationOverrideFile>
+ <DefineConstants>DEBUG;TRACE</DefineConstants>
+ <DocumentationFile>
+ </DocumentationFile>
+ <DebugSymbols>true</DebugSymbols>
+ <FileAlignment>4096</FileAlignment>
+ <NoStdLib>false</NoStdLib>
+ <NoWarn>
+ </NoWarn>
+ <Optimize>false</Optimize>
+ <RegisterForComInterop>false</RegisterForComInterop>
+ <RemoveIntegerChecks>false</RemoveIntegerChecks>
+ <TreatWarningsAsErrors>false</TreatWarningsAsErrors>
+ <WarningLevel>4</WarningLevel>
+ <DebugType>full</DebugType>
+ <ErrorReport>prompt</ErrorReport>
+ </PropertyGroup>
+ <PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">
+ <OutputPath>.\</OutputPath>
+ <AllowUnsafeBlocks>false</AllowUnsafeBlocks>
+ <BaseAddress>285212672</BaseAddress>
+ <CheckForOverflowUnderflow>false</CheckForOverflowUnderflow>
+ <ConfigurationOverrideFile>
+ </ConfigurationOverrideFile>
+ <DefineConstants>TRACE</DefineConstants>
+ <DocumentationFile>
+ </DocumentationFile>
+ <DebugSymbols>false</DebugSymbols>
+ <FileAlignment>4096</FileAlignment>
+ <NoStdLib>false</NoStdLib>
+ <NoWarn>
+ </NoWarn>
+ <Optimize>true</Optimize>
+ <RegisterForComInterop>false</RegisterForComInterop>
+ <RemoveIntegerChecks>false</RemoveIntegerChecks>
+ <TreatWarningsAsErrors>false</TreatWarningsAsErrors>
+ <WarningLevel>4</WarningLevel>
+ <DebugType>none</DebugType>
+ <ErrorReport>prompt</ErrorReport>
+ </PropertyGroup>
+ <ItemGroup>
+ <Reference Include="System">
+ <Name>System</Name>
+ </Reference>
+ <Reference Include="System.Data">
+ <Name>System.Data</Name>
+ </Reference>
+ </ItemGroup>
+ <ItemGroup>
+ <Compile Include="main.cs">
+ <SubType>Code</SubType>
+ </Compile>
+ </ItemGroup>
+ <Import Project="$(MSBuildBinPath)\Microsoft.CSharp.targets" />
+ <PropertyGroup>
+ <PreBuildEvent>
+ </PreBuildEvent>
+ <PostBuildEvent>
+ </PostBuildEvent>
+ </PropertyGroup>
+</Project>
\ No newline at end of file diff --git a/indra/tools/vstool/VSTool.exe b/indra/tools/vstool/VSTool.exe Binary files differnew file mode 100755 index 0000000000..c568c8dd6a --- /dev/null +++ b/indra/tools/vstool/VSTool.exe diff --git a/indra/tools/vstool/VSTool.sln b/indra/tools/vstool/VSTool.sln new file mode 100644 index 0000000000..8859671802 --- /dev/null +++ b/indra/tools/vstool/VSTool.sln @@ -0,0 +1,19 @@ +Microsoft Visual Studio Solution File, Format Version 9.00
+# Visual Studio 2005
+Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "VSTool", "VSTool.csproj", "{96943E2D-1373-4617-A117-D0F997A94919}"
+EndProject
+Global
+ GlobalSection(SolutionConfigurationPlatforms) = preSolution
+ Debug|Any CPU = Debug|Any CPU
+ Release|Any CPU = Release|Any CPU
+ EndGlobalSection
+ GlobalSection(ProjectConfigurationPlatforms) = postSolution
+ {96943E2D-1373-4617-A117-D0F997A94919}.Debug|Any CPU.ActiveCfg = Debug|Any CPU
+ {96943E2D-1373-4617-A117-D0F997A94919}.Debug|Any CPU.Build.0 = Debug|Any CPU
+ {96943E2D-1373-4617-A117-D0F997A94919}.Release|Any CPU.ActiveCfg = Release|Any CPU
+ {96943E2D-1373-4617-A117-D0F997A94919}.Release|Any CPU.Build.0 = Release|Any CPU
+ EndGlobalSection
+ GlobalSection(SolutionProperties) = preSolution
+ HideSolutionNode = FALSE
+ EndGlobalSection
+EndGlobal
diff --git a/indra/tools/vstool/main.cs b/indra/tools/vstool/main.cs new file mode 100644 index 0000000000..0cd57b6b84 --- /dev/null +++ b/indra/tools/vstool/main.cs @@ -0,0 +1,529 @@ +// Code about getting running instances visual studio
+// was borrowed from
+// http://www.codeproject.com/KB/cs/automatingvisualstudio.aspx
+
+
+using System;
+using System.Collections;
+using System.Reflection;
+using System.Runtime.InteropServices;
+using System.Runtime.InteropServices.ComTypes;
+using Microsoft.CSharp;
+
+namespace VSTool
+{
+ class ViaCOM
+ {
+ public static object GetProperty(object from_obj, string prop_name)
+ {
+ Type objType = from_obj.GetType();
+ return objType.InvokeMember(
+ prop_name,
+ BindingFlags.GetProperty, null,
+ from_obj,
+ null);
+ }
+
+ public static object SetProperty(object from_obj, string prop_name, object new_value)
+ {
+ object[] args = { new_value };
+ Type objType = from_obj.GetType();
+ return objType.InvokeMember(
+ prop_name,
+ BindingFlags.DeclaredOnly |
+ BindingFlags.Public |
+ BindingFlags.NonPublic |
+ BindingFlags.Instance |
+ BindingFlags.SetProperty,
+ null,
+ from_obj,
+ args);
+ }
+
+ public static object CallMethod(object from_obj, string method_name, params object[] args)
+ {
+ Type objType = from_obj.GetType();
+ return objType.InvokeMember(
+ method_name,
+ BindingFlags.DeclaredOnly |
+ BindingFlags.Public |
+ BindingFlags.NonPublic |
+ BindingFlags.Instance |
+ BindingFlags.InvokeMethod,
+ null,
+ from_obj,
+ args);
+ }
+ };
+
+ /// <summary>
+ /// The main entry point class for VSTool.
+ /// </summary>
+ class VSToolMain
+ {
+ #region Interop imports
+ [DllImport("ole32.dll")]
+ public static extern int GetRunningObjectTable(int reserved, out IRunningObjectTable prot);
+
+ [DllImport("ole32.dll")]
+ public static extern int CreateBindCtx(int reserved, out IBindCtx ppbc);
+ #endregion
+
+ static System.Boolean ignore_case = true;
+
+ static string solution_name = null;
+ static bool use_new_vs = false;
+ static Hashtable projectDict = new Hashtable();
+ static string startup_project = null;
+ static string config = null;
+
+
+ /// <summary>
+ /// The main entry point for the application.
+ /// </summary>
+ [STAThread]
+ static void Main(string[] args)
+ {
+ bool need_save = false;
+
+ parse_command_line(args);
+
+ Console.WriteLine("Opening solution: {0}", solution_name);
+
+ bool found_open_solution = true;
+
+ Console.WriteLine("Looking for existing VisualStudio instance...");
+
+ // Get an instance of the currently running Visual Studio .NET IDE.
+ object dte = null;
+
+ // dte = (EnvDTE.DTE)System.Runtime.InteropServices.Marshal.GetActiveObject("VisualStudio.DTE.7.1");
+ string full_solution_name = System.IO.Path.GetFullPath(solution_name);
+ if (false == use_new_vs)
+ {
+ dte = GetIDEInstance(full_solution_name);
+ }
+
+ object sol = null;
+
+ if (dte == null)
+ {
+ try
+ {
+ Console.WriteLine(" Didn't find open solution, now opening new VisualStudio instance...");
+ Console.WriteLine(" Reading .sln file version...");
+ string version = GetSolutionVersion(full_solution_name);
+
+ Console.WriteLine(" Opening VS version: {0}...", version);
+ string progid = GetVSProgID(version);
+
+ Type objType = Type.GetTypeFromProgID(progid);
+ dte = System.Activator.CreateInstance(objType);
+
+ Console.WriteLine(" Opening solution...");
+
+ sol = ViaCOM.GetProperty(dte, "Solution");
+ object[] openArgs = {full_solution_name};
+ ViaCOM.CallMethod(sol, "Open", openArgs);
+ }
+ catch( Exception e )
+ {
+ Console.WriteLine(e.Message);
+ Console.WriteLine("Quitting do error opening: {0}", full_solution_name);
+ return;
+ }
+ found_open_solution = false;
+ }
+
+ if (sol == null)
+ {
+ sol = ViaCOM.GetProperty(dte, "Solution");
+ }
+
+ // Walk through all of the projects in the solution
+ // and list the type of each project.
+ foreach(DictionaryEntry p in projectDict)
+ {
+ string project_name = (string)p.Key;
+ string working_dir = (string)p.Value;
+ if(SetProjectWorkingDir(sol, project_name, working_dir))
+ {
+ need_save = true;
+ }
+ }
+
+ if(config != null)
+ {
+ try
+ {
+ object solBuild = ViaCOM.GetProperty(sol, "SolutionBuild");
+ object solCfgs = ViaCOM.GetProperty(solBuild, "SolutionConfigurations");
+ object[] itemArgs = { (object)config };
+ object solCfg = ViaCOM.CallMethod(solCfgs, "Item", itemArgs);
+ ViaCOM.CallMethod(solCfg, "Activate", null);
+ need_save = true;
+ }
+ catch( Exception e )
+ {
+ Console.WriteLine(e.Message);
+ }
+ }
+
+ if (startup_project != null)
+ {
+ try
+ {
+ // You need the 'unique name of the project to set StartupProjects.
+ // find the project by generic name.
+ object prjs = ViaCOM.GetProperty(sol, "Projects");
+ object count = ViaCOM.GetProperty(prjs, "Count");
+ for(int i = 1; i <= (int)count; ++i)
+ {
+ object[] itemArgs = { (object)i };
+ object prj = ViaCOM.CallMethod(prjs, "Item", itemArgs);
+ object prjName = ViaCOM.GetProperty(prj, "Name");
+ if (0 == string.Compare((string)prjName, startup_project, ignore_case))
+ {
+ object solBuild = ViaCOM.GetProperty(sol, "SolutionBuild");
+ ViaCOM.SetProperty(solBuild, "StartupProjects", ViaCOM.GetProperty(prj, "UniqueName"));
+ need_save = true;
+ break;
+ }
+ }
+ }
+ catch (Exception e)
+ {
+ Console.WriteLine(e.Message);
+ }
+ }
+
+ if(need_save)
+ {
+ if(found_open_solution == false)
+ {
+ ViaCOM.CallMethod(sol, "Close", null);
+ }
+ Console.WriteLine("Finished!");
+ }
+ }
+
+ public static bool parse_command_line(string[] args)
+ {
+ string options_desc =
+ "--solution <solution_name> : MSVC solution name. (required)\n" +
+ "--use_new_vs : Ignore running versions of visual studio.\n" +
+ "--workingdir <project> <dir> : Set working dir of a VC project.\n" +
+ "--config <config> : Set the active config for the solution.\n" +
+ "--startup <project> : Set the startup project for the solution.\n";
+
+ try
+ {
+ // Command line param parsing loop.
+ int i = 0;
+ for (; i < args.Length; ++i)
+ {
+ if ("--solution" == args[i])
+ {
+ if (solution_name != null)
+ {
+ throw new ApplicationException("Found second --solution option");
+ }
+ solution_name = args[++i];
+ }
+ else if ("--use_new_vs" == args[i])
+ {
+ use_new_vs = true;
+ }
+
+ else if ("--workingdir" == args[i])
+ {
+ string project_name = args[++i];
+ string working_dir = args[++i];
+ projectDict.Add(project_name, working_dir);
+ }
+ else if ("--config" == args[i])
+ {
+ if (config != null)
+ {
+ throw new ApplicationException("Found second --config option");
+ }
+ config = args[++i];
+ }
+ else if ("--startup" == args[i])
+ {
+ if (startup_project != null)
+ {
+ throw new ApplicationException("Found second --startup option");
+ }
+ startup_project = args[++i];
+ }
+ else
+ {
+ throw new ApplicationException("Found unrecognized token on command line: " + args[i]);
+ }
+ }
+
+ if (solution_name == null)
+ {
+ throw new ApplicationException("The --solution option is required.");
+ }
+ }
+ catch(ApplicationException e)
+ {
+
+ Console.WriteLine("Oops! " + e.Message);
+ Console.Write("Command line:");
+ foreach (string arg in args)
+ {
+ Console.Write(" " + arg);
+ }
+ Console.Write("\n\n");
+ Console.WriteLine("VSTool command line usage");
+ Console.Write(options_desc);
+ throw e;
+ }
+ return true;
+ }
+
+ /// <summary>
+ /// Get the DTE object for the instance of Visual Studio IDE that has
+ /// the specified solution open.
+ /// </summary>
+ /// <param name="solutionFile">The absolute filename of the solution</param>
+ /// <returns>Corresponding DTE object or null if no such IDE is running</returns>
+ public static object GetIDEInstance( string solutionFile )
+ {
+ Hashtable runningInstances = GetIDEInstances( true );
+ IDictionaryEnumerator enumerator = runningInstances.GetEnumerator();
+
+ while ( enumerator.MoveNext() )
+ {
+ try
+ {
+ object ide = enumerator.Value;
+ if (ide != null)
+ {
+ object sol = ViaCOM.GetProperty(ide, "Solution");
+ if (0 == string.Compare((string)ViaCOM.GetProperty(sol, "FullName"), solutionFile, ignore_case))
+ {
+ return ide;
+ }
+ }
+ }
+ catch{}
+ }
+
+ return null;
+ }
+
+ /// <summary>
+ /// Get a table of the currently running instances of the Visual Studio .NET IDE.
+ /// </summary>
+ /// <param name="openSolutionsOnly">Only return instances that have opened a solution</param>
+ /// <returns>A hashtable mapping the name of the IDE in the running object table to the corresponding DTE object</returns>
+ public static Hashtable GetIDEInstances( bool openSolutionsOnly )
+ {
+ Hashtable runningIDEInstances = new Hashtable();
+ Hashtable runningObjects = GetRunningObjectTable();
+
+ IDictionaryEnumerator rotEnumerator = runningObjects.GetEnumerator();
+ while ( rotEnumerator.MoveNext() )
+ {
+ string candidateName = (string) rotEnumerator.Key;
+ if (!candidateName.StartsWith("!VisualStudio.DTE"))
+ continue;
+
+ object ide = rotEnumerator.Value;
+ if (ide == null)
+ continue;
+
+ if (openSolutionsOnly)
+ {
+ try
+ {
+ object sol = ViaCOM.GetProperty(ide, "Solution");
+ string solutionFile = (string)ViaCOM.GetProperty(sol, "FullName");
+ if (solutionFile != String.Empty)
+ {
+ runningIDEInstances[ candidateName ] = ide;
+ }
+ }
+ catch {}
+ }
+ else
+ {
+ runningIDEInstances[ candidateName ] = ide;
+ }
+ }
+ return runningIDEInstances;
+ }
+
+ /// <summary>
+ /// Get a snapshot of the running object table (ROT).
+ /// </summary>
+ /// <returns>A hashtable mapping the name of the object in the ROT to the corresponding object</returns>
+ [STAThread]
+ public static Hashtable GetRunningObjectTable()
+ {
+ Hashtable result = new Hashtable();
+
+ int numFetched = 0;
+ IRunningObjectTable runningObjectTable;
+ IEnumMoniker monikerEnumerator;
+ IMoniker[] monikers = new IMoniker[1];
+
+ GetRunningObjectTable(0, out runningObjectTable);
+ runningObjectTable.EnumRunning(out monikerEnumerator);
+ monikerEnumerator.Reset();
+
+ while (monikerEnumerator.Next(1, monikers, new IntPtr(numFetched)) == 0)
+ {
+ IBindCtx ctx;
+ CreateBindCtx(0, out ctx);
+
+ string runningObjectName;
+ monikers[0].GetDisplayName(ctx, null, out runningObjectName);
+
+ object runningObjectVal;
+ runningObjectTable.GetObject( monikers[0], out runningObjectVal);
+
+ result[ runningObjectName ] = runningObjectVal;
+ }
+
+ return result;
+ }
+
+ public static string GetSolutionVersion(string solutionFullFileName)
+ {
+ string version;
+ System.IO.StreamReader solutionStreamReader = null;
+ string firstLine;
+ string format;
+
+ try
+ {
+ solutionStreamReader = new System.IO.StreamReader(solutionFullFileName);
+ do
+ {
+ firstLine = solutionStreamReader.ReadLine();
+ }
+ while (firstLine == "");
+
+ format = firstLine.Substring(firstLine.LastIndexOf(" ")).Trim();
+
+ switch(format)
+ {
+ case "7.00":
+ version = "VC70";
+ break;
+
+ case "8.00":
+ version = "VC71";
+ break;
+
+ case "9.00":
+ version = "VC80";
+ break;
+
+ case "10.00":
+ version = "VC90";
+ break;
+ default:
+ throw new ApplicationException("Unknown .sln version: " + format);
+ }
+ }
+ finally
+ {
+ if(solutionStreamReader != null)
+ {
+ solutionStreamReader.Close();
+ }
+ }
+
+ return version;
+ }
+
+ public static string GetVSProgID(string version)
+ {
+ string progid = null;
+ switch(version)
+ {
+ case "VC70":
+ progid = "VisualStudio.DTE.7";
+ break;
+
+ case "VC71":
+ progid = "VisualStudio.DTE.7.1";
+ break;
+
+ case "VC80":
+ progid = "VisualStudio.DTE.8.0";
+ break;
+
+ case "VC90":
+ progid = "VisualStudio.DTE.9.0";
+ break;
+ default:
+ throw new ApplicationException("Can't handle VS version: " + version);
+ }
+
+ return progid;
+ }
+
+ public static bool SetProjectWorkingDir(object sol, string project_name, string working_dir)
+ {
+ bool made_change = false;
+ Console.WriteLine("Looking for project {0}...", project_name);
+ try
+ {
+ object prjs = ViaCOM.GetProperty(sol, "Projects");
+ object count = ViaCOM.GetProperty(prjs, "Count");
+ for(int i = 1; i <= (int)count; ++i)
+ {
+ object[] prjItemArgs = { (object)i };
+ object prj = ViaCOM.CallMethod(prjs, "Item", prjItemArgs);
+ string name = (string)ViaCOM.GetProperty(prj, "Name");
+ if (0 == string.Compare(name, project_name, ignore_case))
+ {
+ Console.WriteLine("Found project: {0}", project_name);
+ Console.WriteLine("Setting working directory");
+
+ string full_project_name = (string)ViaCOM.GetProperty(prj, "FullName");
+ Console.WriteLine(full_project_name);
+
+ // *NOTE:Mani Thanks to incompatibilities between different versions of the
+ // VCProjectEngine.dll assembly, we can't cast the objects recevied from the DTE to
+ // the VCProjectEngine types from a different version than the one built
+ // with. ie, VisualStudio.DTE.7.1 objects can't be converted in a project built
+ // in VS 8.0. To avoid this problem, we can use the com object interfaces directly,
+ // with out the type casting. Its tedious code, but it seems to work.
+
+ // oCfgs should be assigned to a 'Project.Configurations' collection.
+ object oCfgs = ViaCOM.GetProperty(ViaCOM.GetProperty(prj, "Object"), "Configurations");
+
+ // oCount will be assigned to the number of configs present in oCfgs.
+ object oCount = ViaCOM.GetProperty(oCfgs, "Count");
+
+ for (int cfgIndex = 1; cfgIndex <= (int)oCount; ++cfgIndex)
+ {
+ object[] itemArgs = {(object)cfgIndex};
+ object oCfg = ViaCOM.CallMethod(oCfgs, "Item", itemArgs);
+ object oDebugSettings = ViaCOM.GetProperty(oCfg, "DebugSettings");
+ ViaCOM.SetProperty(oDebugSettings, "WorkingDirectory", (object)working_dir);
+ }
+
+ break;
+ }
+ }
+ made_change = true;
+ }
+ catch( Exception e )
+ {
+ Console.WriteLine(e.Message);
+ Console.WriteLine("Failed settings working dir for project, {0}.", project_name);
+ }
+
+ return made_change;
+ }
+ }
+}
|