summaryrefslogtreecommitdiff
path: root/indra/newview/installers/windows
diff options
context:
space:
mode:
authorbrad kittenbrink <brad@lindenlab.com>2010-11-19 15:40:05 -0800
committerbrad kittenbrink <brad@lindenlab.com>2010-11-19 15:40:05 -0800
commitfd78866bcdf712aaefecfb74d7edaecb30c91b27 (patch)
tree235398d36401c68fc841389bb11984d94d36d7db /indra/newview/installers/windows
parent3337ef16cee97e26b45aa07518d34d031bdc75fa (diff)
parentb6edd74775e07ce392b0a1785cfc61338c890dad (diff)
Merged latest lindenlab/viewer-development with mani_linden/viewer-development
Diffstat (limited to 'indra/newview/installers/windows')
-rw-r--r--indra/newview/installers/windows/installer_template.nsi55
1 files changed, 39 insertions, 16 deletions
diff --git a/indra/newview/installers/windows/installer_template.nsi b/indra/newview/installers/windows/installer_template.nsi
index d5712f80cf..4e8ed807ee 100644
--- a/indra/newview/installers/windows/installer_template.nsi
+++ b/indra/newview/installers/windows/installer_template.nsi
@@ -85,6 +85,8 @@ AutoCloseWindow true ; after all files install, close window
InstallDir "$PROGRAMFILES\${INSTNAME}"
InstallDirRegKey HKEY_LOCAL_MACHINE "SOFTWARE\Linden Research, Inc.\${INSTNAME}" ""
DirText $(DirectoryChooseTitle) $(DirectoryChooseSetup)
+Page directory dirPre
+Page instfiles
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;; Variables
@@ -95,6 +97,8 @@ Var INSTFLAGS
Var INSTSHORTCUT
Var COMMANDLINE ; command line passed to this installer, set in .onInit
Var SHORTCUT_LANG_PARAM ; "--set InstallLanguage de", passes language to viewer
+Var SKIP_DIALOGS ; set from command line in .onInit. autoinstall
+ ; GUI and the defaults.
;;; Function definitions should go before file includes, because calls to
;;; DLLs like LangDLL trigger an implicit file include, so if that call is at
@@ -110,6 +114,9 @@ Var SHORTCUT_LANG_PARAM ; "--set InstallLanguage de", passes language to viewer
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
Function .onInstSuccess
Push $R0 # Option value, unused
+
+ StrCmp $SKIP_DIALOGS "true" label_launch
+
${GetOptions} $COMMANDLINE "/AUTOSTART" $R0
# If parameter was there (no error) just launch
# Otherwise ask
@@ -128,6 +135,13 @@ label_no_launch:
Pop $R0
FunctionEnd
+;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
+;;; Pre-directory page callback
+;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
+Function dirPre
+ StrCmp $SKIP_DIALOGS "true" 0 +2
+ Abort
+FunctionEnd
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
; Make sure we're not on Windows 98 / ME
@@ -145,7 +159,8 @@ Function CheckWindowsVersion
StrCmp $R0 "NT" win_ver_bad
Return
win_ver_bad:
- MessageBox MB_YESNO $(CheckWindowsVersionMB) IDNO win_ver_abort
+ StrCmp $SKIP_DIALOGS "true" +2 ; If skip_dialogs is set just install
+ MessageBox MB_YESNO $(CheckWindowsVersionMB) IDNO win_ver_abort
Return
win_ver_abort:
Quit
@@ -184,13 +199,13 @@ FunctionEnd
; If it has, allow user to bail out of install process.
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
Function CheckIfAlreadyCurrent
- Push $0
- ReadRegStr $0 HKEY_LOCAL_MACHINE "SOFTWARE\Linden Research, Inc.\$INSTPROG" "Version"
- StrCmp $0 ${VERSION_LONG} 0 DONE
- MessageBox MB_OKCANCEL $(CheckIfCurrentMB) /SD IDOK IDOK DONE
+ Push $0
+ ReadRegStr $0 HKEY_LOCAL_MACHINE "SOFTWARE\Linden Research, Inc.\$INSTPROG" "Version"
+ StrCmp $0 ${VERSION_LONG} 0 continue_install
+ StrCmp $SKIP_DIALOGS "true" continue_install
+ MessageBox MB_OKCANCEL $(CheckIfCurrentMB) /SD IDOK IDOK continue_install
Quit
-
- DONE:
+continue_install:
Pop $0
Return
FunctionEnd
@@ -203,7 +218,9 @@ Function CloseSecondLife
Push $0
FindWindow $0 "Second Life" ""
IntCmp $0 0 DONE
- MessageBox MB_OKCANCEL $(CloseSecondLifeInstMB) IDOK CLOSE IDCANCEL CANCEL_INSTALL
+
+ StrCmp $SKIP_DIALOGS "true" CLOSE
+ MessageBox MB_OKCANCEL $(CloseSecondLifeInstMB) IDOK CLOSE IDCANCEL CANCEL_INSTALL
CANCEL_INSTALL:
Quit
@@ -659,23 +676,29 @@ FunctionEnd
Function .onInit
Push $0
${GetParameters} $COMMANDLINE ; get our command line
+
+ ${GetOptions} $COMMANDLINE "/SKIP_DIALOGS" $0
+ IfErrors +2 0 ; If error jump past setting SKIP_DIALOGS
+ StrCpy $SKIP_DIALOGS "true"
+
${GetOptions} $COMMANDLINE "/LANGID=" $0 ; /LANGID=1033 implies US English
; If no language (error), then proceed
- IfErrors lbl_check_silent
+ IfErrors lbl_configure_default_lang
; No error means we got a language, so use it
StrCpy $LANGUAGE $0
Goto lbl_return
-lbl_check_silent:
- ; For silent installs, no language prompt, use default
- IfSilent lbl_return
-
- ; If we currently have a version of SL installed, default to the language of that install
+lbl_configure_default_lang:
+ ; If we currently have a version of SL installed, default to the language of that install
; Otherwise don't change $LANGUAGE and it will default to the OS UI language.
- ReadRegStr $0 HKEY_LOCAL_MACHINE "SOFTWARE\Linden Research, Inc.\${INSTNAME}" "InstallerLanguage"
- IfErrors lbl_build_menu
+ ReadRegStr $0 HKEY_LOCAL_MACHINE "SOFTWARE\Linden Research, Inc.\${INSTNAME}" "InstallerLanguage"
+ IfErrors +2 0 ; If error skip the copy instruction
StrCpy $LANGUAGE $0
+ ; For silent installs, no language prompt, use default
+ IfSilent lbl_return
+ StrCmp $SKIP_DIALOGS "true" lbl_return
+
lbl_build_menu:
Push ""
# Use separate file so labels can be UTF-16 but we can still merge changes